Conductivity meter Portavo 902 Cond/904 Cond/904 X Cond

Knick Elektronische (1317)

Conductivity meter Portavo 902 Cond/904 Cond/904 X Cond
Portavo 902 Cond
-The basic version for mobile conductivity measurement
-Robust, intuitive portable device for routine daily measurements in laboratories and processes
-A sensor quiver protects the sensor from drying...
Conductivity meter Portavo 902 Cond/904 Cond/904 X Cond
Portavo 902 Cond
-The basic version for mobile conductivity measurement
-Robust, intuitive portable device for routine daily measurements in laboratories and processes
-A sensor quiver protects the sensor from drying out or being damaged in daily use
-The high-performance polymer housing ensures low water absorption and high impact resistance
-Over 1000 hours of measurement with a single set of batteries (4 x AA)
-Memosens sensors and analog sensors can be used on the same device
-The mineral glass display is perfectly readable even after years

Portavo 904 Cond
as Portavo 902 Cond, additionally with:
-Li-ion battery
-Data logger with 5,000 values
-Micro USB port and Paraly SW 112 software

Portavo 904 X Cond
as Portavo 904 Cond, additionally with:
-Conductivity measurement with ATEX approval for measurements up to Zone 0/1. Ideal for applications in the process industry. For the first time, Portavo enables direct on-site testing of process measuring points.
-The new MemoLog function allows the user to log calibration data from various Memosens measuring points
Specifications
Measuring range (Accuracy): 0.001 µS/cm (c0.2 cm-1)
TDS:
Salinity: 0 ... 1999 mg/l
0.0 ... 45.0 g/kg
Resistivity:
Concentration: 00.00 ... 99.99 MO x cm
0.00 ... 9.99 (w/w) %
Conductivity input, analog: Multi-contact for 2-/4-electrode sensors with integrated temp detector
Measuring ranges
Sensor SE 202:
Sensor SE 204:
0.01 ... 200 µS/cm
1 µS/cm ... 500 mS/cm
2-electrode sensors:
4-electrode sensors: 0.1 µS x c ... 200 mS x c
0.1 µS x c ... 1000 mS x c
Temperature input: 2 x 4 mm diam. for integrated or separate temperature detector
Messbereich mit NTC 30 kO:
Messbereich mit Pt 1000: -20 ... 120 °C
-40 ... 250 °C
Conductivity input, Memosens: M8 socket, 4 pins, for Memosens lab cable
Measuring range sensor SE 215 MS: 10 µS/cm ... 20 mS/cm
Conductivity input
Temperature compensation: Linear 0 ... 20 %/K, reference temperature adjustable
nLF: 0 ... 120 °C
Power supply:
Protection class acc. to DIN EN 60529: 4 x AA
IP66/67 with pressure compensation
PN Manuf. PN Supplier PK Type General Price Quantity Status Add
9774710 902 COND Knick Elektronische 1 902 Cond 1388.24 EU Search Please contact us
9774712 904 COND Knick Elektronische 1 904 Cond 1929.41 EU Search Please contact us
9774715 904 X COND Knick Elektronische 1 904 X Cond 2835.29 EU Search Please contact us